Ultrasonic Flow Meter PCE-TDS 100HMHS
£ 2,069.00
Price excl. VAT &. delivery
2 year Warranty
The ultrasonic flow meter is required as part of a control measurement or to quickly determine the flow in a pipeline and is a portable / easy-to-install measuring system. The ultrasonic flow meter works according to the transit time difference method. The measuring principle of the flow meter is quite simple.

- Measuring range: -32 ... 32 m/s, -105 ... 105 ft/s
- Resolution: 0.0001 m/s, 0.00033 ft/s
Pipe size: DN 50 … 720 mm, DN 20 …108 mm
- Sensor temperature range: 32 ... 320°F
- Sensor installation: V, Z
- incl. sensors TDS-HM and TDS-HS on rails
Clamp-on Ultrasonic Flow Meter PCE-TDS 100HMHS-ICA incl. ISO Calibration Certificate
£ 2,305.00
Price excl. VAT &. delivery
2 year Warranty
ISO Calibration
The Clamp-on Ultrasonic Flow Meter is required as part of a control measurement or to quickly determine the flow in a pipeline and is a portable / easy-to-install measuring system. The Clamp-on Ultrasonic Flow Meter works according to the transit time difference method. The measuring principle of the flow meter is quite simple.

- Measuring range: -32 ... 32 m/s, -105 ... 105 ft/s
- Resolution: 0.0001 m/s, 0.00033 ft/s
- Pipe sizes: 50 … 720 mm (approx. 1.9 … 28")
                      20 …108 mm (approx. 0.8 … 4.2")
- Sensor temperature range: 0 ... 160°C / 32 ... 320°F
- Sensor installation: V, Z
- Incl. sensors TDS-HM and TDS-HS on rails
- Incl. ISO Calibration Certificate
Flow Meter PCE-TDS 100HMHS-ICA incl. ISO Calibration Certificate
£ 2,305.00
Price excl. VAT &. delivery
2 year Warranty
ISO Calibration
The flow meter is required as part of a control measurement or to quickly determine the flow in a pipeline and is a portable / easy-to-install measuring system. The flow meter works according to the transit time difference method. The measuring principle of the flow meter is quite simple.

- Measuring range: -32 ... 32 m/s, -105 ... 105 ft/s
- Resolution: 0.0001 m/s, 0.00033 ft/s
- Pipe sizes: 50 … 720 mm (approx. 1.9 … 28")
                      20 …108 mm (approx. 0.8 … 4.2")
- Sensor temperature range: 0 ... 160°C / 32 ... 320°F
- Sensor installation: V, Z
- Incl. sensors TDS-HM and TDS-HS on rails
- Incl. ISO Calibration Certificate
HVAC Meter PCE-TDS 100HMHS-ICA incl. ISO Calibration Certificate
£ 2,305.00
Price excl. VAT &. delivery
2 year Warranty
ISO Calibration

The HVAC meter is required as part of a control measurement or to quickly determine the flow in a pipeline and is a portable / easy-to-install measuring system. The HVAC meter works according to the transit time difference method. The measuring principle of the HVAC meter is quite simple.


- Measuring range: -32 ... 32 m/s, -105 ... 105 ft/s
- Resolution: 0.0001 m/s, 0.00033 ft/s
- Pipe sizes: 50 … 720 mm (approx. 1.9 … 28")
                      20 …108 mm (approx. 0.8 … 4.2")
- Sensor temperature range: 0 ... 160°C / 32 ... 320°F
- Sensor installation: V, Z
- Incl. sensors TDS-HM and TDS-HS on rails
- Incl. ISO Calibration Certificate

Ultrasonic Flow Meter PCE-TDS 100HMHS-ICA incl. ISO Calibration Certificate
£ 2,305.00
Price excl. VAT &. delivery
2 year Warranty
ISO Calibration
The ultrasonic flow meter is required as part of a control measurement or to quickly determine the flow in a pipeline and is a portable / easy-to-install measuring system. The ultrasonic flow meter works according to the transit time difference method. The measuring principle of the flow meter is quite simple.

- Measuring range: -32 ... 32 m/s, -105 ... 105 ft/s
- Resolution: 0.0001 m/s, 0.00033 ft/s
Pipe size: DN 50 … 720 mm / DN 20 …108 mm 
- Sensor temperature range:  32 ... 320°F
- Sensor installation: V, Z
- Incl. sensors TDS-HM and TDS-HS on rails
- Incl. ISO Calibration Certificate
Ultrasonic Flow Tester PCE-TDS 100HMHS-ICA incl. ISO Calibration Certificate
£ 2,305.00
Price excl. VAT &. delivery
2 year Warranty
ISO Calibration
The ultrasonic flow tester is required as part of a control measurement or to quickly determine the flow in a pipeline and is a portable / easy-to-install measuring system. The ultrasonic flow tester works according to the transit time difference method. The measuring principle of the flow tester is quite simple.

- Measuring range: -32 ... 32 m/s, -105 ... 105 ft/s
- Resolution: 0.0001 m/s, 0.00033 ft/s
- Pipe sizes: 50 … 720 mm (approx. 1.9 … 28")
                      20 …108 mm (approx. 0.8 … 4.2")
- Sensor temperature range: 0 ... 160°C / 32 ... 320°F
- Sensor installation: V, Z
- Incl. sensors TDS-HM and TDS-HS on rails
- Incl. ISO Calibration Certificate
HVAC Meter PCE-TDS 100HMHS
£ 2,069.00
Price excl. VAT &. delivery
2 year Warranty
The HVAC meter is required as part of a control measurement or to quickly determine the flow in a pipeline and is a portable / easy-to-install measuring system. The HVAC meter works according to the transit time difference method. The measuring principle of the flow meter is quite simple.

- Measuring range: -32 ... 32 m/s, -105 ... 105 ft/s
- Resolution: 0.0001 m/s, 0.00033 ft/s
- Pipe sizes: 50 … 720 mm (approx. 1.9 … 28")
                      20 …108 mm (approx. 0.8 … 4.2")
- Sensor temperature range: 0 ... 160°C / 32 ... 320°F
- Sensor installation: V, Z
- Incl. sensors TDS-HM and TDS-HS on rails
Portable Ultrasonic Flow Meter PCE-TDS 100HMHS
£ 2,069.00
Price excl. VAT &. delivery
2 year Warranty
The Portable Ultrasonic Flow Meter is required as part of a control measurement or to quickly determine the flow in a pipeline and is a portable / easy-to-install measuring system. The Portable Ultrasonic Flow Meter works according to the transit time difference method. The measuring principle of the flow meter is quite simple.

- Measuring range: -32 ... 32 m/s, -105 ... 105 ft/s
- Resolution: 0.0001 m/s, 0.00033 ft/s
- Pipe sizes: 50 … 720 mm (approx. 1.9 … 28")
                      20 …108 mm (approx. 0.8 … 4.2")
- Sensor temperature range: 0 ... 160°C / 32 ... 320°F
- Sensor installation: V, Z
- Incl. sensors TDS-HM and TDS-HS on rails
Ultrasonic Flow Tester PCE-TDS 100HMHS
£ 2,069.00
Price excl. VAT &. delivery
2 year Warranty
The ultrasonic flow tester is required as part of a control measurement or to quickly determine the flow in a pipeline and is a portable / easy-to-install measuring system. The ultrasonic flow tester works according to the transit time difference method. The measuring principle of the flow tester is quite simple.

- Measuring range: -32 ... 32 m/s, -105 ... 105 ft/s
- Resolution: 0.0001 m/s, 0.00033 ft/s
- Pipe sizes: 50 … 720 mm (approx. 1.9 … 28")
                      20 …108 mm (approx. 0.8 … 4.2")
- Sensor temperature range: 0 ... 160°C / 32 ... 320°F
- Sensor installation: V, Z
- Incl. sensors TDS-HM and TDS-HS on rails
Material Hardness Tester PCE-5000
£ 5,251.00
Price excl. VAT &. delivery
2 year Warranty

PCE-5000 is a portable material hardness tester that uses the ASTM A1038 ultrasonic contact impedance (UCI) method to measure the hardness of metals and alloys with a minimum thickness of 2 mm / .08 in. Non-destructive testing produces microscopic indentation.

- Measurement according to ASTM A1038 ultrasonic contact impedance (UCI) method
- Measurement units: Rockwell A (HRA), Rockwell B (HRB), Rockwell C (HRC), Brinell (HB), Vickers (HV) and MPa (N/mm²) SI units
- Measurement ranges: 61-85.6 HRA, 41-100 HRB, 20.3-68 HRC, 85-650 HB, 50-999 HV, 255-2180 MPa (N/mm²)
- Accuracy: ± 1.5 HR, ± 3% HB, ± 3% HV, Repeatability: ± 0.3%
- Memory size: 1,000 groups for measurement data and 20 groups for calibration data
- Different probe types (also automatic motorized probes) available

Material Hardness Tester PCE-5000
£ 5,251.00
Price excl. VAT &. delivery
2 year Warranty

PCE-5000 is a portable material hardness tester that uses the ASTM A1038 ultrasonic contact impedance (UCI) method to measure the hardness of metals and alloys with a minimum thickness of 2 mm / .08 in. Non-destructive testing produces microscopic indentation.

- Measurement according to ASTM A1038 ultrasonic contact impedance (UCI) method
- Measurement units: Rockwell A (HRA), Rockwell B (HRB), Rockwell C (HRC), Brinell (HB), Vickers (HV) and MPa (N/mm²) SI units
- Measurement ranges: 61-85.6 HRA, 41-100 HRB, 20.3-68 HRC, 85-650 HB, 50-999 HV, 255-2180 MPa (N/mm²)
- Accuracy: ± 1.5 HR, ± 3% HB, ± 3% HV, Repeatability: ± 0.3%
- Memory size: 1,000 groups for measurement data and 20 groups for calibration data
- Different probe types (also automatic motorized probes) available

Metal Hardness Tester PCE-5000
£ 5,251.00
Price excl. VAT &. delivery
2 year Warranty

PCE-5000 is a portable material hardness tester that uses the ASTM A1038 ultrasonic contact impedance (UCI) method to measure the hardness of metals and alloys with a minimum thickness of 2 mm / .08 in. Non-destructive testing produces microscopic indentation.

- Measurement according to ASTM A1038 ultrasonic contact impedance (UCI) method
- Measurement units: Rockwell A (HRA), Rockwell B (HRB), Rockwell C (HRC), Brinell (HB), Vickers (HV) and MPa (N/mm²) SI units
- Measurement ranges: 61-85.6 HRA, 41-100 HRB, 20.3-68 HRC, 85-650 HB, 50-999 HV, 255-2180 MPa (N/mm²)
- Accuracy: ± 1.5 HR, ± 3% HB, ± 3% HV, Repeatability: ± 0.3%
- Memory size: 1,000 groups for measurement data and 20 groups for calibration data
- Different probe types (also automatic motorized probes) available

NDT Test Instruments PCE-5000
£ 5,251.00
Price excl. VAT &. delivery
2 year Warranty

PCE-5000 is a portable hardness tester that uses the ASTM A1038 ultrasonic contact impedance (UCI) method to measure the hardness of metals and alloys with a minimum thickness of 2 mm / .08 in Non-destructive testing produces microscopic indentation.

- Measurement according to ASTM A1038 ultrasonic contact impedance (UCI) method
- Measurement units: Rockwell A (HRA), Rockwell B (HRB), Rockwell C (HRC), Brinell (HB), Vickers (HV) and MPa (N/mm²) SI units
- Measurement ranges: 61-85.6 HRA, 41-100 HRB, 20.3-68 HRC, 85-650 HB, 50-999 HV, 255-2180 MPa (N/mm²)
- Accuracy: ± 1.5 HR, ± 3% HB, ± 3% HV, Repeatability: ± 0.3%
- Memory size: 1,000 groups for measurement data and 20 groups for calibration data
- Different probe types (also automatic motorized probes) available

UCI Durometer PCE-5000
£ 5,251.00
Price excl. VAT &. delivery
2 year Warranty

PCE-5000 is a portable hardness tester or durometer that uses the ASTM A1038 ultrasonic contact impedance (UCI) method to measure the hardness of metals and alloys to measure on a minimum material thickness of 2 mm / .08 in. The test instrument can be mounted on a test stand (as an option) for series measurement in manufacturing process checking. Non-destructive testing produces microscopic indentation.

- Measurement according to ASTM A1038 ultrasonic contact impedance (UCI) method
- Measurement units: Rockwell A (HRA), Rockwell B (HRB), Rockwell C (HRC), Brinell (HB), Vickers (HV) and MPa (N/mm²) SI units
- Measurement ranges: 61-85.6 HRA, 41-100 HRB, 20.3-68 HRC, 85-650 HB, 50-999 HV, 255-2180 MPa (N/mm²)
- Accuracy: ± 1.5 HR, ± 3% HB, ± 3% HV, Repeatability: ± 0.3%
- Memory size: 1,000 groups for measurement data and 20 groups for calibration data
- Different probe types (also automatic motorized probes) available

UCI Hardness Tester PCE-5000
£ 5,251.00
Price excl. VAT &. delivery
2 year Warranty

PCE-5000 is a portable hardness tester that uses the ASTM A1038 ultrasonic contact impedance (UCI) method to measure the hardness of metals and alloys with a minimum thickness of 2 mm / .08 in Non-destructive testing produces microscopic indentation.

- Measurement according to ASTM A1038 ultrasonic contact impedance (UCI) method
- Measurement units: Rockwell A (HRA), Rockwell B (HRB), Rockwell C (HRC), Brinell (HB), Vickers (HV) and MPa (N/mm²) SI units
- Measurement ranges: 61-85.6 HRA, 41-100 HRB, 20.3-68 HRC, 85-650 HB, 50-999 HV, 255-2180 MPa (N/mm²)
- Accuracy: ± 1.5 HR, ± 3% HB, ± 3% HV, Repeatability: ± 0.3%
- Memory size: 1,000 groups for measurement data and 20 groups for calibration data
- Different probe types (also automatic motorized probes) available

Ultrasonic / UCI Hardness Tester PCE-5000
£ 5,251.00
Price excl. VAT &. delivery
2 year Warranty

PCE-5000 is a portable hardness tester that uses the ASTM A1038 ultrasonic contact impedance (UCI) method to measure the hardness of metals and alloys with a minimum thickness of 2 mm / .08 in. Non-destructive testing produces microscopic indentation.

- Measurement according to ASTM A1038 ultrasonic contact impedance (UCI) method
- Measurement units: Rockwell A (HRA), Rockwell B (HRB), Rockwell C (HRC), Brinell (HB), Vickers (HV) and MPa (N/mm²) SI units
- Measurement ranges: 61-85.6 HRA, 41-100 HRB, 20.3-68 HRC, 85-650 HB, 50-999 HV, 255-2180 MPa (N/mm²)
- Accuracy: ± 1.5 HR, ± 3% HB, ± 3% HV, Repeatability: ± 0.3%
- Memory size: 1,000 groups for measurement data and 20 groups for calibration data
- Different probe types (also automatic motorized probes) available

Platform Scale PCE-WWSB8-S
£ 2,354.00
Price excl. VAT &. delivery
2 year Warranty

PCE-WWSB8-S is a portable platform scale consisting of two weighing platforms and a carrying case with a built-in display and printer. Featuring connections for up to four weighing platforms (additional weighing platforms sold separately - see accessories), this floor scale calculates the total weight, wheel load and axle load of a vehicle.


- Weighing capacity per platform (wheel load): 8000 kg / 17636 lbs / 8.8 T
- Sum function for calculating vehicle weight plus trailer
- IP65 ingress protection rating on load cell for outdoor use

Portable Industrial Floor Scale PCE-WWSB8-S
£ 2,354.00
Price excl. VAT &. delivery
2 year Warranty

PCE-WWSB8-S is a portable industrial floor scale consisting of two weighing platforms and a carrying case with a built-in display and printer. Featuring connections for up to four weighing platforms (additional weighing platforms sold separately - see accessories), this floor scale calculates the total weight, wheel load and axle load of a vehicle.


- Weighing capacity per platform (wheel load): 8000 kg / 17636 lbs / 8.8 T
- Sum function for calculating vehicle weight plus trailer
- IP65 ingress protection rating on load cell for outdoor use