2 year Warranty
Clamp on Tester with network Analyzer / Clamp on Tester with data logger. The Clamp on Tester (Graphic Power Quality Analyzer) PCE-GPA 62 is used for single-phase or three-phase measurements of the active, reactive and apparent power, power factor, phase angle, energy, voltage, current as well as peaks and harmonics up to 50? of the harmonic waveform. As all test instruments, the Clamp on Tester is delivered manufacturer calibrated (ISO certification is available optional).
- Real-time test, register and measurement of voltage and current (real and effective)
- Measures power factor and phase angle, frequency, energy, active, reactive and apparent power
(single-phase or three-phase in symmetrical networks).
- Max. conductor diameter: 55 mm / 2.2 in
- Records up to 50,000 records
The clamp on tester PCE-DC 41 can measure voltages up to 600 V, currents up to 600 A and electrical resistance up to 1000 Ω. To perform a measurement, you can either use the measuring leads, which are included in the package of the clamp on tester, or you can use the integrated clamp mechanism. By using the clamp of the clamp on tester, you are able to measure the electrical parameters of an electrical conductor contact-free and without disconnecting it.
- Voltage: 600 V AC/DC
- Current: 600 A AC/DC
- Electrical Resistance: 1000 Ω
- Clamp mechanism
- Incl. ISO Calibration Certificate
The clamp on tester PCE-DC 41 can measure voltages up to 600 V, currents up to 600 A and electrical resistance up to 1000 Ω. To perform a measurement, you can either use the measuring leads, which are included in the package of the clamp on tester, or you can use the integrated clamp mechanism. By using the clamp of the clamp on tester, you are able to measure the electrical parameters of an electrical conductor contact-free and without disconnecting it.
- Voltage: 600 V AC/DC
- Current: 600 A AC/DC
- Electrical Resistance: 1000 Ω
- Clamp mechanism
The PCE-830 Clamp on Tester is used for measuring one to three phases of electrical quantities for alternating current (AC). This Clamp on Tester also measures such parameters as voltage, current, frequency, harmonics and power as well as indicating, according to standard EN50160, harmonic values, interharmonics and asymmetrics. Interference, such as interruptions, leaks, overloads or transience (from 16µs) are detected with their corresponding values.
- PCE-830 + PCE-6802 amp clamp (1000 A)
- Electrical conductor pick-up: 55 mm / 2.2 in diameter
- Range selection: manual (10 A, 100 A, 1000 A)
- Clamp dimensions: 244 x 97 x 46 mm / 9.6 x 3.8 x 1.8 in
- Incl. ISO calibration certificate
The PCE-830-2 Clamp on Tester is used for measuring one to three phases of electrical quantities for alternating current (AC). This Clamp on Tester also measures parameters such as voltage, current, frequency, harmonics, and power as well as indicating, according to standard EN50160, harmonic values, interharmonics, and asymmetrics. Interference, such as interruptions, leaks, overloads, or transience (from 16 µs) are detected with their corresponding values. The power logging instrument is delivered manufacturer calibrated. An ISO calibration certificate may be ordered optionally.
- PCE-830 + PCE-6802 amp clamp (1000 A)
- Electrical conductor pick-up: 55 mm / 2.1 in diameter
- Range selection: manual (10 A, 100 A, 1000 A)
- Clamp dimensions: 244 mm x 97 mm x 46 mm / 9.6 in x 3.7 in x 1.8 in
- Sampling rate: 2 sec.
- Memory size: 512 kB (max. 52,000 values (single phase)
Clamp on Tester to test leakage / RMS measurement / continuity and resistance test. The Clamp on Tester can measure leakage currents which appear when current flows through electrical conductors which are not designed for conduction current. The Clamp on Tester, as all test instruments, is delivered manufacturer calibrated, but can additionally be certified to ISO.
- Measures current up to 100 A
- Measures voltage up to 600 V
- Measures resistance up to 400 O
- Test cables are included
The PCE-830-3 Clamp on Tester is used for measuring one to three phases of electrical quantities for alternating current (AC). This Clamp on Tester also measures such parameters as voltage, current, frequency, harmonics and power as well as indicating, according to standard EN50160, harmonic values, interharmonics and asymmetrics. Interference, such as interruptions, leaks, overloads or transience (from 16µs) are detected with their corresponding values.
- PCE-830 + PCE-3007 flexible amp clamp (3000A)
- Electrical conductor pick-up: 170 mm / 6.7 in diameter
- Minimum radial curve: 35 mm / 1.4 in
- Length of electrical conductor: 610 mm / 24 in
- Sampling rate: 2 sec.
- Memory size: 512 kB / max. 52,420 data (1 phase)
- Incl. ISO calibration certificate
The PCE-830 Clamp on Tester is used for measuring one to three phases of electrical quantities for alternating current (AC). This Clamp on Tester also measures parameters such as voltage, current, frequency, harmonics, and power as well as indicating, according to standard EN50160, harmonic values, interharmonics, and asymmetrics. Interference, such as interruptions, leaks, overloads, or transience (from 16 µs) are detected with their corresponding values. The power logging instrument is delivered manufacturer calibrated. An ISO calibration certificate may be ordered optionally.
- PCE-830 + PCE-6801 amp clamp (100 A)
- Electrical conductor pick-up: 30 mm / 1.1 in diameter
- Range selection: manual (1 A, 10 A, 100 A)
- Clamp dimensions: 210 mm x 62 mm x 36 mm / 8.2 in x 2.4 in x 1.4 in
- Sampling rate: 2 sec.
- Memory size: 512 kB (max. 52,000 values (single phase)
This clamp on tester is used for single-phase or three-phase measurements of the active, reactive and apparent power, power factor, phase angle, energy, voltage, current as well as peaks and harmonics up to 50º of the harmonic waveform. The clamp on tester is equipped with data logger. The test instrument is delivered manufacturer calibrated (ISO or certification as an option).
- Real-time test, register and measurement of voltage and current (real and effective)
- Measures power factor and phase angle, frequency, energy, active, reactive and apparent power
(single-phase or three-phase in symmetrical networks).
- Max. conductor diameter: 55 mm / 2.2 in
- Datalogger for 50,000 readings / software/ USB interface
- incl. ISO Calibration Certificate
The PCE-830-3 Clamp on Tester is used for measuring one to three phases of electrical quantities for alternating current (AC). This Clamp on Tester also measures parameters such as voltage, current, frequency, harmonics, and power as well as indicating, according to standard EN50160, harmonic values, interharmonics, and asymmetrics. Interference, such as interruptions, leaks, overloads, or transience (from 16 µs) are detected with their corresponding values. The power logging instrument is delivered manufacturer calibrated. An ISO calibration certificate may be ordered optionally.
- PCE-830 + PCE-3007 flexible amp clamp (3000 A)
- Electrical conductor pick-up: 170 mm / 6.69 in diameter
- Length of electrical conductor: 610 mm / 24.0 in
- Dimensions: 257 mm x 155 mm x 57 mm / 10.1 in x 6.1 in x 2.2 in
- Sampling rate: 2 sec.
- Memory size: 512 kB (max. 52,000 values - single phase)