Clamp on Tester PCE-GPA 62
£ 845.00
Price excl. VAT &. delivery
2 year Warranty

Clamp on Tester with network Analyzer / Clamp on Tester with data logger. The Clamp on Tester (Graphic Power Quality Analyzer) PCE-GPA 62 is used for single-phase or three-phase measurements of the active, reactive and apparent power, power factor, phase angle, energy, voltage, current as well as peaks and harmonics up to 50? of the harmonic waveform. As all test instruments, the Clamp on Tester is delivered manufacturer calibrated (ISO certification is available optional).


- Real-time test, register and measurement of voltage and current (real and effective) 
- Measures power factor and phase angle, frequency, energy, active, reactive and apparent power 
  (single-phase or three-phase in symmetrical networks). 
- Max. conductor diameter: 55 mm / 2.2 in
- Records up to 50,000 records


Clamp on Tester PCE-DC 41-ICA incl. ISO Calibration Certificate
£ 308.00
Price excl. VAT &. delivery
2 year Warranty
ISO Calibration

The clamp on tester PCE-DC 41 can measure voltages up to 600 V, currents up to 600 A and electrical resistance up to 1000 Ω. To perform a measurement, you can either use the measuring leads, which are included in the package of the clamp on tester, or you can use the integrated clamp mechanism. By using the clamp of the clamp on tester, you are able to measure the electrical parameters of an electrical conductor contact-free and without disconnecting it.


- Voltage: 600 V AC/DC
- Current: 600 A AC/DC
- Electrical Resistance: 1000 Ω
- Clamp mechanism
- Incl. ISO Calibration Certificate

Clamp on Tester PCE-DC 41
£ 182.00
Price excl. VAT &. delivery
2 year Warranty

The clamp on tester PCE-DC 41 can measure voltages up to 600 V, currents up to 600 A and electrical resistance up to 1000 Ω. To perform a measurement, you can either use the measuring leads, which are included in the package of the clamp on tester, or you can use the integrated clamp mechanism. By using the clamp of the clamp on tester, you are able to measure the electrical parameters of an electrical conductor contact-free and without disconnecting it.


- Voltage: 600 V AC/DC
- Current: 600 A AC/DC
- Electrical Resistance: 1000 Ω
- Clamp mechanism

 

Clamp on Tester PCE-MCM 10-ICA incl. ISO Calibration Certificate
£ 392.00
Price excl. VAT &. delivery
2 year Warranty
ISO Calibration
The clamp on tester has a measurement range of ±99.9 mA DC. With an accuracy of 0.3% of rdg. +8 digits, the clamp on tester is a particularly accurate measuring instrument. In order to conveniently perform measurements with the clamp on tester, the current clamp itself is connected to a 1 meter / 3.3 ft cable.

- Measuring range 1: ±20.99 mA DC
- Measuring range 2: ±21.0 … ±99.9 mA DC
- Diameter of clamp opening: Ø5 mm
- Detachable clamp on tester with 1 m / 3.3 ft cable
- Incl. ISO Calibration Certificate
Clamp on Tester PCE-830-2-ICA incl. ISO Calibration Certificate
£ 2,827.00
Price excl. VAT &. delivery
2 year Warranty
ISO Calibration

The PCE-830 Clamp on Tester is used for measuring one to three phases of electrical quantities for alternating current (AC). This Clamp on Tester also measures such parameters as voltage, current, frequency, harmonics and power as well as indicating, according to standard EN50160, harmonic values, interharmonics and asymmetrics. Interference, such as interruptions, leaks, overloads or transience (from 16µs) are detected with their corresponding values.


- PCE-830 + PCE-6802 amp clamp (1000 A)
- Electrical conductor pick-up: 55 mm / 2.2 in diameter
- Range selection: manual (10 A, 100 A, 1000 A)
- Clamp dimensions: 244 x 97 x 46 mm / 9.6 x 3.8 x 1.8 in
- Incl. ISO calibration certificate

Clamp on Tester PCE-CM 3-ICA incl. ISO Calibration Certificate
£ 194.00
Price excl. VAT &. delivery
2 year Warranty
ISO Calibration
The clamp on tester is used for quick and easy AC measurements. For current measurement, the clamp on tester is plugged over the live conductor. The clamp on tester is particularly suitable for the measurement of alternating current in distributions and wherever circuits must not be interrupted.

- Digital Multimeters up to 200 A
- Compact dimensions
- Robust plastic housing
- Multimeter functions
- Safety conditions: IEC1010-1 (2001)
                             CAT II 1000V
                             CAT III 600V
- Incl. ISO Calibration Certificate
Clamp on Tester PCE-LCT 1-ICA incl. ISO Calibration Certificate
£ 273.00
Price excl. VAT &. delivery
2 year Warranty
ISO Calibration
With the Clamp on Tester, it is possible to measure leakage currents in the range of up to 100A. Leakage occurs when a current flows through an electrical conductor that is not normally designed to conduct electricity. The Clamp on Tester captures these currents and displays them on the display. 

- Measurable electrical parameters: AC V, AC A, resistance
- Clamp diameter: 30 mm
- Operating temperature: -10 ... 50°C / 50 ... 122°F
- Current consumption: 10-mA
- Incl. ISO calibration certificate
Clamp on Tester PCE-MCM 10
£ 254.00
Price excl. VAT &. delivery
2 year Warranty
No-Shopping
The clamp on tester has a measurement range of ±99.9 mA DC. With an accuracy of 0.3% of rdg. +8 digits, the clamp on tester is a particularly accurate measuring instrument. In order to conveniently perform measurements with the clamp on tester, the current clamp itself is connected to a 1 meter / 3.3 ft cable.

- Measuring range 1: ±20.99 mA DC
- Measuring range 2: ±21.0 … ±99.9 mA DC
- Diameter of clamp opening: Ø5 mm
- Detachable clamp on tester with 1 m / 3.3 ft cable
Clamp on Tester PCE-830-2
£ 2,398.00
Price excl. VAT &. delivery
2 year Warranty

The PCE-830-2 Clamp on Tester is used for measuring one to three phases of electrical quantities for alternating current (AC). This Clamp on Tester also measures parameters such as voltage, current, frequency, harmonics, and power as well as indicating, according to standard EN50160, harmonic values, interharmonics, and asymmetrics. Interference, such as interruptions, leaks, overloads, or transience (from 16 µs) are detected with their corresponding values. The power logging instrument is delivered manufacturer calibrated. An ISO calibration certificate may be ordered optionally.


- PCE-830 + PCE-6802 amp clamp (1000 A)
- Electrical conductor pick-up: 55 mm / 2.1 in diameter
- Range selection: manual (10 A, 100 A, 1000 A)
- Clamp dimensions: 244 mm x 97 mm x 46 mm / 9.6 in x 3.7 in x 1.8 in
- Sampling rate: 2 sec.
- Memory size: 512 kB (max. 52,000 values (single phase)

Clamp on Tester PCE-PA 8500-ICA incl. ISO-Calibration Certificate
£ 3,302.00
Price excl. VAT &. delivery
2 year Warranty
ISO Calibration
The clamp on tester redefines standards in electrical measurement technology, offering a comprehensive range of features for precise and detailed measurements. The clamp on tester allows accurate measurements of electrical voltage, current, frequency, harmonics, and starting currents. In addition, precise power and energy measurements can be performed, enabling accurate monitoring and optimization of energy consumption.

- Voltages: 1 ... 1000 V
- Current: 15 ... 3000 A AC
- Graphical representation of waveform and vector graphics
- Data logger with 8 GB storage
- LAN and USB data interface
- Includes flexible current clamps
- Compliance with standards: IEC61000-4-30, 61000-4-15, 
  61000-4-7, EN50160
- incl. ISO-Calibration Certificate
Clamp on Tester PCE-LCT 1
£ 159.00
Price excl. VAT &. delivery
2 year Warranty

Clamp on Tester to test leakage / RMS measurement / continuity and resistance test. The Clamp on Tester can measure leakage currents which appear when current flows through electrical conductors which are not designed for conduction current. The Clamp on Tester, as all test instruments, is delivered manufacturer calibrated, but can additionally be certified to ISO.


- Measures current up to 100 A
- Measures voltage up to 600 V
- Measures resistance up to 400 O
- Test cables are included

 

Clamp on Tester PCE-PA 8500
£ 2,916.00
Price excl. VAT &. delivery
2 year Warranty
The clamp on tester redefines standards in electrical measurement technology, offering a comprehensive range of features for precise and detailed measurements. The clamp on tester allows accurate measurements of electrical voltage, current, frequency, harmonics, and starting currents. In addition, precise power and energy measurements can be performed, enabling accurate monitoring and optimization of energy consumption.

- Voltages: 1 ... 1000 V
- Current: 15 ... 3000 A AC
- Graphical representation of waveform and vector graphics
- Data logger with 8 GB storage
- LAN and USB data interface
- Includes flexible current clamps
- Compliance with standards: IEC61000-4-30, 61000-4-15, 
  61000-4-7, EN50160
Clamp on Tester PCE-830-3-ICA incl. ISO Calibration Certificate
£ 2,554.00
Price excl. VAT &. delivery
2 year Warranty
ISO Calibration

The PCE-830-3 Clamp on Tester is used for measuring one to three phases of electrical quantities for alternating current (AC). This Clamp on Tester also measures such parameters as voltage, current, frequency, harmonics and power as well as indicating, according to standard EN50160, harmonic values, interharmonics and asymmetrics. Interference, such as interruptions, leaks, overloads or transience (from 16µs) are detected with their corresponding values.


- PCE-830 + PCE-3007 flexible amp clamp (3000A)
- Electrical conductor pick-up: 170 mm / 6.7 in diameter
- Minimum radial curve: 35 mm / 1.4 in
- Length of electrical conductor: 610 mm / 24 in
- Sampling rate: 2 sec.
- Memory size: 512 kB / max. 52,420 data (1 phase)
- Incl. ISO calibration certificate

Clamp on Tester PCE-830-1
£ 2,127.00
Price excl. VAT &. delivery
2 year Warranty

The PCE-830 Clamp on Tester is used for measuring one to three phases of electrical quantities for alternating current (AC). This Clamp on Tester also measures parameters such as voltage, current, frequency, harmonics, and power as well as indicating, according to standard EN50160, harmonic values, interharmonics, and asymmetrics. Interference, such as interruptions, leaks, overloads, or transience (from 16 µs) are detected with their corresponding values. The power logging instrument is delivered manufacturer calibrated. An ISO calibration certificate may be ordered optionally.


- PCE-830 + PCE-6801 amp clamp (100 A)
- Electrical conductor pick-up: 30 mm / 1.1 in diameter
- Range selection: manual (1 A, 10 A, 100 A)
- Clamp dimensions: 210 mm x 62 mm x 36 mm / 8.2 in x 2.4 in x 1.4 in
- Sampling rate: 2 sec.
- Memory size: 512 kB (max. 52,000 values (single phase)

Clamp on Tester PCE-GPA 62-ICA incl. ISO Calibration Certificate
£ 958.00
Price excl. VAT &. delivery
2 year Warranty
ISO Calibration

This clamp on tester is used for single-phase or three-phase measurements of the active, reactive and apparent power, power factor, phase angle, energy, voltage, current as well as peaks and harmonics up to 50º of the harmonic waveform. The clamp on tester is equipped with data logger. The test instrument is delivered manufacturer calibrated (ISO or certification as an option).


- Real-time test, register and measurement of voltage and current (real and effective) 
- Measures power factor and phase angle, frequency, energy, active, reactive and apparent power 
  (single-phase or three-phase in symmetrical networks). 
- Max. conductor diameter: 55 mm / 2.2 in
- Datalogger for 50,000 readings / software/ USB interface 
- incl. ISO Calibration Certificate

Clamp on Tester PCE-830-3
£ 2,127.00
Price excl. VAT &. delivery
2 year Warranty

The PCE-830-3 Clamp on Tester is used for measuring one to three phases of electrical quantities for alternating current (AC). This Clamp on Tester also measures parameters such as voltage, current, frequency, harmonics, and power as well as indicating, according to standard EN50160, harmonic values, interharmonics, and asymmetrics. Interference, such as interruptions, leaks, overloads, or transience (from 16 µs) are detected with their corresponding values. The power logging instrument is delivered manufacturer calibrated. An ISO calibration certificate may be ordered optionally.


- PCE-830 + PCE-3007 flexible amp clamp (3000 A)
- Electrical conductor pick-up: 170 mm / 6.69 in diameter
- Length of electrical conductor: 610 mm / 24.0 in
- Dimensions: 257 mm x 155 mm x 57 mm / 10.1 in x 6.1 in x 2.2 in
- Sampling rate: 2 sec.
- Memory size: 512 kB (max. 52,000 values - single phase)

Clamp on Tester PCE-CM 3
£ 80.00
Price excl. VAT &. delivery
2 year Warranty
The clamp on tester is used for quick and easy AC measurements. For current measurement, the clamp on tester is plugged over the live conductor. The clamp on tester is particularly suitable for the measurement of alternating current in distributions and wherever circuits must not be interrupted.

- Digital Multimeters up to 200 A
- Compact dimensions
- Robust plastic housing
- Multimeter functions
- Safety conditions: IEC1010-1 (2001)
                             CAT II 1000V
                             CAT III 600V
Clamp on Tester PCE-CM 5
£ 58.00
Price excl. VAT &. delivery
2 year Warranty
The clamp on tester is a multimeter with a multitude of different functions. Thus, with the clamp on tester, current measurements up to 200 A AC can be carried out without contact. This current range of the clamp on tester already covers a large range of current measurements. 

Measurement function:
- AC
- DC
- DC voltage
- AC voltage
- LowZ AC / DC
- Resistance
- Continuity test
- Diode test
- Capacities
- Temperature (type K)
- Frequency (with the current clamp)
- Frequency (during voltage measurement)
- frequency (direct measurement)
- Duty cycle